background image

 

12 

 

Sunny 

Cloudy 

Rainy 

To stop the alarm, press any key (except the DISPL and 

 

keys

)

 during alarm ringing. Or press and hold 

the SNOOZE key for 2 seconds (a beep sound can be heard). 
 

WEATHER FORECAST AND WEATHER TENDENCY INDICATOR: 
 
 
 
 
 
 

 
 

 

WEATHER FORECAST ICONS 

The weather forecast can be displayed a s follow: 

 
 
 
 
 
 

 

For every sudden or significant change in the air pressure, the weather icons will update accordingly to 
represent the change in weather. If the icons do not change, then it means either the air pressure has not 
changed or the change has been too slow for the weather projection station to register. However, if the icon 
displayed is a sun or raining cloud, there will be no change of icon if the weather gets any better (with sunny 
icon) or worse (with rainy icon) since the icons are already at their extremes. 

 

The icons displayed forecasts the weather in terms of getting better or worse and not necessarily sunny or 
rainy as each icon indicates. For example, if the current weather is cloudy and the rainy icon is displayed, it 
does not mean that the product is faulty because it is not raining. It simply means that the air pressure has 
dropped and the weather is expected to get worse but not necessarily rainy. 

 

Note:

 

 

After setting up, readings for weather forecasts should be disregarded for the next 12-24 hours. This will 
allow sufficient time for the weather projection station to collect air pressure data at a constant altitude and 
therefore result in a more accurate forecast. 

 

Common to weather forecasting, absolute accuracy cannot be guaranteed. The weather forecasting feature 
is estimated to have an accuracy level of about 75% due to the varying areas the weather projection station 
has been designed for use. In areas that experience sudden changes in weather (for example from sunny to 
rain), the weather projection station will be more accurate compared to use in areas where the weather is 
stagnant most of the time (for example mostly sunny). 

 

If the weather projection station is moved to another location significantly higher or lower than its initial 
standing point (for example from the ground floor to the upper floors of a house), discard the weather 
forecast for the next 12-24 hours. By doing this, the weather projection station will not mistake the new 
location as being a possible change in air-pressure when really it is due to the slight change of altitude.  
 

 

Weather Boy icon 

Weather tendency indicator

Weather forecast icon 

Summary of Contents for WS-9520U

Page 1: ...calendar moon phase indoor and outdoor temperature indoor and outdoor relative humidity this unit will never keep you guessing on current and future weather conditions Operation of this product is sim...

Page 2: ...n orientation possible LCD contrast selectable E L back light Low battery indicator Table standing AC DC power adapter included The Remote Temperature Humidity Sensor Remote transmission of outdoor te...

Page 3: ...data is displayed proceed to step 2 2 Within 4 minutes of activating the weather projection station place the batteries into the remote temperature humidity sensor see To install and replace batterie...

Page 4: ...ries and wait for at least 3 minutes before reinserting them 2 Within 4 minutes of activating the weather projection station place the batteries into the remote temperature humidity sensor see To inst...

Page 5: ...humidity sensor need to be reset when one of the following conditions occur Unsuccessful 433MHz signal reception Malfunction of the units Batteries need replacement For resetting remove all batteries...

Page 6: ...me announced at the top of the minute in Coordinated Universal Time which is also known as Greenwich Mean Time GMT This time does not follow Daylight Saving Time changes After the top of the minute a...

Page 7: ...on HOUR IN key Press to set the alarm hour inside alarm setting mode Press shortly to toggle between MIN MAX and current indoor temperature and humidity data Press and hold for 4 seconds to reset the...

Page 8: ...er identification number Outdoor relative humidity in RH WWVB Signal Reception Icon LCD SCREEN The LCD screen is split into 5 sections displaying the information for time date weather forecast indoor...

Page 9: ...be adjusted according to Daylight Saving Time in the spring and fall For areas that do not recognize DST changes Arizona and parts of Indiana turn the DST OFF 1 The digit ON will start flashing on th...

Page 10: ...set time into the received time During reception attempts the WWVB tower icon will flash If reception has been unsuccessful then the WWVB tower icon will not appear but reception will still be attempt...

Page 11: ...ations with rapid changes of weather conditions the weather icons can be set to a different level for faster display of weather conditions 1 The current sensitivity value will start flashing 2 Use the...

Page 12: ...in the air pressure the weather icons will update accordingly to represent the change in weather If the icons do not change then it means either the air pressure has not changed or the change has bee...

Page 13: ...te Once the weather tendency indicator has registered a change in air pressure it will remain permanently visualized on the LCD WEATHER BOY FORECASTING ICONS A total of 24 Weather Boy icons combinatio...

Page 14: ...3 Three times to return to transmitter 1 Note The transmitter number will only be displayed if there is more than one transmitter being used 3 To reset the MIN MAX outdoor temperature and the time at...

Page 15: ...ment and interference levels If no reception is possible despite the observation of these factors all system units have to be reset see Setting up above POSITIONING THE REMOTE TEMPERATURE HUMIDITY SEN...

Page 16: ...0 2 x 169 6 x 74 4 mm Remote temperature humidity sensor 6 29 x 1 69 x 0 90 inches 160 x 43 x 23 mm LIABILITY DISCLAIMER The manufacturer and supplier cannot accept any responsibility for any incorrec...

Page 17: ...warranty covers only actual defects within the product itself and does not cover the cost of installation or removal from a fixed installation normal set up or adjustments claims based on misrepresen...

Page 18: ...ICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT INTERFERENCE RECEIVED INC...

Reviews: