background image

CONTENTS

Topic

Page

Introduction

3

Features

4

Quick set up guide

5

Detailed set up guide

6

Function keys

10

Operations

11

Mounting

18

Troubleshooting

21

Maintenance and care

23

Specifications

24

Warranty information

25

Language

Page

English

2

French

30

Spanish

59

This product offers:

WS-9029U

915 MHz

Wireless Weather Station

Instruction Manual

Contents

GB

GB

P.3

GB

P.4

GB

P.5

INSTANT TRANSMISSION
is the state-of-the-art new
w i r e l e s s   t r a n s m i s s i o n
technology, exclusively de-

s i g n e d   a n d   d ev e l o p e d   b y   L A   C R O S S E
TECHNOLOGY. 

INSTANT TRANSMISSION offers

you can an immediate update (every 4 seconds!) of
all your outdoor data measured from the
transmitters: follow your climatic variations in real-
time!

FEATURES

Wireless Weather Station (Figure 1).

Remote Temperature Sensor with optional

Channel 2 Probe (TX25U, Figure 2).

Indoor Temperature (˚F or ˚C) and Indoor Humidity.

Wireless Outdoor Temperature (˚F or ˚C).

Optional Channel 2 Temperature Probe.

Able to Receive up to 3 Remote Temperature

Sensors.

Wall Hanging or Free Standing.

ADDITIONAL EQUIPMENT (not included)

1. Two fresh AA 1.5V alkaline batteries for the wire-

less weather station.

2. Two fresh AAA 1.5V alkaline batteries for the re-

mote temperature sensor.

3. One, Philips screwdriver for mounting.

QUICK SETUP

Hint: Use good quality Alkaline Batteries; avoid re-

chargeable batteries.

1. Have the Wireless Weather Station and Tempera-

ture sensor 3 to 5 feet apart.

2. Batteries should be out of both units for 10 minutes.

3. Place the batteries into the Temperature sensor

first and next into the Wireless Weather Station.

4. DO NOT PRESS ANY BUTTONS FOR 15

MINUTES.

In this time the Wireless Weather Station and the tem-

perature sensor will begin to communicate with each

other, and the display will show both the indoor tem-

perature and an outdoor temperature.  If the Wireless

12 or 24 Hour
Time Display

Connection w/
Sensor Icon

Low Battery
Indicator

Set / Channel
Button

Indoor Temperature
(˚F or ˚C)

Indoor Humidity
(%RH)

Channel Indicatop (1, 2
or 3)

Outdoor Temperature
(˚F or ˚C)

Minimum or Maximmum
Temperature &
Humidity

Minimum/Maximum/
+Button

Figure 1

Optional Probe
w/ 10 Foot Wire

Remote
Temperature
Sensor LCD
Temperature
Display

Wall-Mounting
Bracket

Figure 2

P.2

FCC ID: OMOTX25U (transmitter)
RF Exposure mobile:
The internal / external antennas used for this mobile transmitter must pro-
vide a separation distance of at least 20 cm (8 inches) from all persons and
must not be co-located or operating in conjunction with any other antenna
or transmitter.”

Statement according to FCC part 15.19:
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, in-
cluding interference that may cause undesired operation.

Statement according to FCC part 15.21:
Modifications not expressly approved by this company could void the user’s
authority to operate the equipment.

Statement according to FCC part 15.105:
NOTE:
 This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful inter-
ference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in accor-
dance with the instructions, may cause harmful interference to radio
communications.
However, there is no guarantee that interference will not occur in a particu-
lar installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to

which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help

Summary of Contents for WS-9029U

Page 1: ...re F or C Indoor Humidity RH Channel Indicatop 1 2 or 3 Outdoor Temperature F or C Minimum or Maximmum Temperature Humidity Minimum Maximum Button Figure 1 Optional Probe w 10 Foot Wire Remote Tempera...

Page 2: ...and release the SET CH button once 4 The hour will begin flashing 5 Press and release the MIN MAX button to ad vance the hours 6 Press and release the SET CH button once more and the minutes will beg...

Page 3: ...the Minimum Maximum temperature first select which remote temperature sensor to read data from indicated by the boxed number then press the SET CH button Pressing this button once will display the mi...

Page 4: ...charges incurred in getting your La CrosseTechnology Ltd prod uct to a La Crosse Technology Ltd authorized service center La Crosse Technology Ltd will pay ground re turn shipping charges to the owne...

Page 5: ...pluie directe GUIDE DE MONTAGE DETAILLE I MISE EN PLACE DES PILES Avec utilisation d un capteur de temp rature 1 Commencer par installer les piles dans le capteur de temp rature voir A Capteur de tem...

Page 6: ...nnect e au capteur de temp rature distance le canal 1 du WS 9029U affiche les donn es de ce capteur Les donn es du capteur de temp rature distance s affichent toujours sur le canal 1 et la sonde de te...

Page 7: ...du capteur de temp rature distance requiert une courbe de calibrage diff rente du rayon int rieur Les erreurs sont g n ralement plus importantes aux extr mit s d un rayon ce qui fait qu il est d autan...

Page 8: ...e peut tre ni reproduit sous quelque forme que ce soit m me sous forme d extraits ni copi ni trait par proc dure lectronique m canique ou chimique sans l accord crit de l diteur Ce manuel peut conteni...

Page 9: ...ning n bot n Esto puede interferir con la recepci n de la se al ocasionando lecturas incorrectas de la temperatura 1 Quite la Tapa de las pilas colocada en la parte trasera de la Estaci n 2 Instale 2...

Page 10: ...das y volver a reinstalarlas desde el paso 1 5 Si esta utilizando la sonda entonces se visualizar la temperatura respectiva por el canal 2 Si no en la secci n de la temperatura exterior aparecer el s...

Page 11: ...exacta ESPECIFICACIONES TECNICAS Rango de medici n de la Temperatura Interior 14 1 F a 139 8 F con una resoluci n de 0 2 F 9 9 C a 59 8 C con una resoluci n de 0 1 C Muestra el s mbolo OFL si esta po...

Page 12: ...a asistencia t cnica o informaci n por favor contacte La Crosse Technology Ltd 2809 Losey Blvd South La Crosse WI 54601 Tel fono 608 782 1610 Fax 608 796 1020 e mail support lacrossetechnology com tra...

Reviews: