background image

 

WS-9016U 

Wireless 433 MHz 

Radio-controlled  

Sun/Moon Weather Station 

 

Instruction Manual

 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

 

Summary of Contents for WS-9016U

Page 1: ...WS 9016U Wireless 433 MHz Radio controlled Sun Moon Weather Station Instruction Manual ...

Page 2: ...ur Setting 12 Manual Time Setting 13 Calendar Setting 14 Snooze Setting 15 ºF ºC Setting 15 Weather Forecast Icon Sensitivity Setting 16 Features Alarm Setting 16 17 Sunrise set Moonrise set Information 17 18 Moon Phase Symbols 18 Indoor Temperature and Humidity 18 Weather Forecast and Tendency 19 20 Outdoor Temperature 20 21 Adding Remote Temperature Sensors 21 22 Set up of Multiple Remote Temper...

Page 3: ...ape 5 Instruction manual and warranty card ADDITIONAL EQUIPMENT not included 1 Two fresh AA 1 5V batteries for indoor weather station 2 Two fresh AA 1 5V batteries for remoter temperature sensor 3 One Philips screwdriver for mounting Time LCD Sun moon LCD Forecast LCD Indoor LCD Outdoor LCD Figure 1 Hanging hole Battery compartment Removable stand Figure 2 Mounting Bracket Battery compartment ...

Page 4: ...ather station However due to the nature of the earth s ionosphere reception is very limited during daylight hours The weather station will search for a signal every night when reception is best The WWVB radio station derives its signal from the NIST Atomic clock in Boulder Colorado A team of atomic physicists is continually measuring every second of every day to an accuracy of ten billionths of a ...

Page 5: ...utes you can place your remote temperature sensor outdoors and set your time The remote temperature sensor should be placed in a dry shaded area The remote temperature sensor has a range of 80 feet Any walls that the signal will have to pass through will reduce distance An outdoor wall or window will have 20 to 30 feet of resistance and an interior wall will have 10 to 20 feet of resistance Your d...

Page 6: ...sition of the battery cover then push up and pull out on the battery cover 2 Observe the correct polarity and install 2 AA batteries 3 Replace the battery cover Note Immediately after the batteries have been installed each LCD Liquid Crystal Display will flash and a tone will sound Within a few seconds the indoor temperature indoor relative humidity and the weather icons sun and clouds will be dis...

Page 7: ...t panel of the Weather Station and 2 on the front 1 SET button Enter manual setting modes LCD contrast city location time zone DST ON OFF WWVB ON OFF 12 24 hour display manual time setting calendar snooze function temperature C or F and weather icon sensitivity setting Stop the alarm during alarm ringing 2 PLUS button Increase value in all setting modes Increase the digits Stop the alarm during al...

Page 8: ...more than one sensor is used Pressed together with MAX MIN R button for 3 sec allows temperature channel reset Exit any set mode anytime during setting and to return to the normal display mode Stop the alarm during alarm ringing 8 MAX MIN R button Max min Reset Press shortly to toggle between maximum minimum and current temperature value for selected outdoor temperature channel Press and hold for ...

Page 9: ...e setting WWVB ON OFF setting 12 24 Hour setting Manual time setting Calendar setting Snooze setting C F setting Weather forecasting icon sensitivity setting Sunset time Moon icon Moon phases icon Moonset time Weather tendency indicator Time Date display Indoor relative humidity in RH Sun icon City location light Time reception icon for WWVB time Alarm icon Moonrise time Sunrise time Indoor temper...

Page 10: ...her station to see the 45 preset city names list Any city can be selected in order to view the sun moon data the default city is Washington D C To select a city 1 Open the left panel on the weather station List of cities are displayed 2 Use the PLUS or MINUS to select a city 3 A small dot displayed on the left side of the LCD will light up next to the city name 4 When a city is selected the city s...

Page 11: ... highlights the selected time zone for 5hr EST 6hr CST 7hr MST and 8hr PST zones 5 Press and release the SET button to confirm and enter the DST Daylight Saving Time setting DST Daylight Saving Time Setting Note The DST default is ON meaning that the received time will automatically be adjusted according to Daylight Saving Time in the spring and fall For areas that do not recognize DST changes Ari...

Page 12: ... button to confirm and enter the 12 24 HOUR setting Note If the WWVB time reception function is turned OFF the clock will not attempt any reception of the WWVB time signal as long as the WWVB OFF function is activated The WWVB reception icon will not be displayed on the LCD 12 24 Hour Setting The hour display can be selected to show the hours in 12 hour or 24 hour format the default format is 12 H...

Page 13: ...ss and release the PLUS button or MINUS button to set the minutes 6 Press and release the SET button to confirm and enter the Calendar setting Note The unit will still try to receive the signal between 12 00 to 6 00 a m every day despite it being manually set and as long as the WWVB reception function has been set ON When it does receive the signal it will change the manually set time into the rec...

Page 14: ... MINUS button to set the year 3 Press and release the SET button to confirm the year and to enter the month setting 4 The month starts flashing 5 Press and release the PLUS or MINUS button to set the month 6 Press and release the SET button to confirm the month and to enter the date setting mode 7 The date starts flashing 8 Press and release the PLUS or MINUS button to set the date 9 Press and rel...

Page 15: ...OFF when the OFF digit is being displayed 3 Press and release the SET button to confirm and enter the Temperature setting Note If the snooze time has been set OFF the snooze function will not be activated F C Temperature Setting The temperature display can be selected to show temperature data in C or F the default setting is F 1 The digits ºF will start flashing in the LCD 2 Press and release the ...

Page 16: ...lt setting is 2 4 Press and release the SET button to confirm and exit the Manual settings To Exit The Manual Setting Mode To exit the manual setting mode anytime during the manual setting modes press the CHANNEL button anytime or wait for automatic timeout The mode will return to the normal time display III FEATURES OF THE WS 9016U Alarm Setting The alarm time can be set by pressing the ALARM SET...

Page 17: ...he snooze setting Otherwise the snooze function will not be activated To stop the alarm press any button during alarm ringing SUN MOON DATA AND MOON PHASES Sun Moon Data For Selected City 1 The sunrise sunset and moonrise moonset time for each of the preset cities can be displayed by pressing the SUN MOON button 2 Press and release the PLUS or MINUS button to choose any city from the list 3 The sm...

Page 18: ...rise moonset time Moon Phase Symbols The moon icon of the weather station will also display all 12 moon phases throughout the year accordingly to the set calendar Note It may happen that there is no moonrise or moonset on a certain date consequently 1 above the moonrise or moonset time will be displayed to indicate that it will occur at the displayed time the next day Indoor Relative Humidity and ...

Page 19: ...icons are already at their extremes The icons displayed forecasts the weather in terms of getting better or worse and not necessarily sunny or rainy as each icon indicates For example if the current weather is cloudy and the rainy icon is displayed it does not mean that the product is faulty because it is not raining This simply means that the air pressure has dropped and the weather is expected t...

Page 20: ...er is expected to improve but when indicator points downwards the air pressure is dropping and the weather is expected to become worse Taking this into account one can see how the weather has changed and is expected to change For example if the indicator is pointing downwards together with cloud and sun icons then the last noticeable change in the weather was when it was sunny the sun icon only Th...

Page 21: ... the selected remote temperature sensor ADDING OUTDOOR REMOTE TEMPERATURE SENSORS OPTIONAL The WS 9016U is able to receive signals from 3 different remote temperature sensors The remote temperature sensor model s that you choose will come with their own set of instructions Follow these instructions for a complete guide to setting up Following are some brief instructions for the basic set up of rem...

Page 22: ... to receive WWVB signals from the desired location Also extreme and sudden changes in temperature will decrease the accuracy of the indoor weather station and changes in elevation will result with inaccurate weather forecasting for the next 12 to 24 hours These changes will require a 12 to 24 hour wait before obtaining reliable data To achieve a true temperature reading avoid mounting where direct...

Page 23: ...ew the mounting bracket onto the mounting surface 6 Ensure that the screws are flush with the bracket B MOUNTING WITH ADHESIVE TAPE 1 With a nonabrasive solution clean and dry the back of the mounting bracket and the mounting surface to ensure a secure hold The mounting surface should be smooth and flat 2 Remove the protective strip from one side of the tape 3 Adhere the tape to the designated are...

Page 24: ...o use the table stand all that is required is to place the indoor temperature station in an appropriate location B WALL MOUNTING 1 Remove the table stand To do this pull down on the stand from the rear and rotate forward 2 Fix a screw not included into the desired wall leaving approximately 3 16 of an inch 5mm extended from the wall 3 Place the indoor temperature station onto the screw using the h...

Page 25: ...land Maine Detroit Michigan St Paul Minnesota St Louis Missouri Jackson Mississippi Helena Montana Raleigh North Carolina Bismarck North Dakota Omaha Nebraska Albuquerque New Mexico Las Vegas Nevada Reno Nevada New York City New York Cincinnati Ohio Oklahoma City Oklahoma Salem Oregon Philadelphia Pennsylvania Pittsburgh Pennsylvania Columbia South Carolina Pierre South Dakota Nashville Tennessee ...

Page 26: ...e are correct Solution Be sure correct time zone and daylight saving time are selected Problem The LCD is faint Solution 1 Set the LCD contrast to a higher number 2 Replace batteries Problem No remote temperature is displayed Solution 1 Remove all batteries reinsert into remote sensor s first then indoor weather station 2 Place remote sensor s closer to indoor weather station 3 Be sure all batteri...

Page 27: ... displays and units with a soft damp cloth Do not use solvents or scouring agents They may mark the displays and casings Do not submerge in water Immediately remove all low powered batteries to avoid leakage and damage Opening the casings invalidates the warranty Do not try to repair the unit Contact La Crosse Technology for repairs ...

Page 28: ...king interval Every 15 seconds Indoor humidity checking interval Every 20 seconds Outdoor temperature checking interval Remote Temperature Sensor Every 1 minute Outdoor temperature reception Indoor Weather Station Every 5 minutes Transmission Range 80 feet in open space Power Supply Indoor Weather Station 2 x AA IEC LR6 1 5V Remote Temperature Sensor 2 x AA IEC LR6 1 5V Battery life cycle Approxim...

Page 29: ...ed for the repairs or examination The owner must pay any shipping charges incurred in getting your La Crosse Technology Ltd product to a La Crosse Technology Ltd authorized service center La Crosse Technology Ltd will pay ground return shipping charges to the owner of the product to a USA address only Your La Crosse Technology Ltd warranty covers all defects in material and workmanship with the fo...

Page 30: ...information contact La Crosse Technology 2809 Losey Blvd S La Crosse WI 54601 Phone 608 782 1610 Fax 608 796 1020 e mail support lacrossetechnology com warranty work sales lacrossetechnology com information on other products web www lacrossetechnology com FCC ID OMO 01RX Receiver OMO 01TX sensor THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS...

Page 31: ...etroit Michigan St Paul Minnesota St Louis Missouri Jackson Mississippi Helena Montana Raleigh North Carolina Bismarck North Dakota Omaha Nebraska Albuquerque New Mexico Las Vegas Nevada Reno Nevada New York City New York Cincinnati Ohio Oklahoma City Oklahoma Salem Oregon Philadelphia Pennsylvania Pittsburgh Pennsylvania Columbia South Carolina Pierre South Dakota Nashville Tennessee Dallas Texas...