![La Cornue CornuFe Service Instructions Manual Download Page 10](http://html2.mh-extra.com/html/la-cornue/cornufe/cornufe_service-instructions-manual_3104995010.webp)
10
Checking the Cooktop
Range Maintop
Ignition
The maintop burners have spark ignition operated by a switch on each control valve. When any burner control
knob is pressed in the spark generator module produces sparks at all the burners ignition electrodes.
Problem
Check
The ignition system
makes sparks but does
not light the gas
Try lighting the burner with a match.
Are the fl ames even around the head with a blueish color?
Check the burner head is clean and the fl ame ports are clear. Check that the burner head is sitting
down correctly on the burner base.
What gas is being used? The range is supplied set for Natural Gas. It must be converted before it
can be used on LP gas.
The ignition system
does not make sparks.
Use fl ow chart below to check out the ignition system
Summary of Contents for CornuFe
Page 7: ...7 Checking the Multifunction Oven...
Page 9: ...9 Checking the Convection Oven...
Page 34: ......
Page 35: ......
Page 36: ...060106...