When required by the manufacturer’s control drawing, the associated apparatus must be
connected to a suitable ground electrode per the National Electrical Code (ANSI/NFPA 70),
the Canadian Electrical Code, or other local installation codes, as applicable. The resistance
of the ground path must be less than 1 ohm.
•
Associated apparatus must not be used in combination unless permitted by the associated
apparatus certification.
EXPLOSION HAZARD / AVERTISSEMENT - RISQUE D’EXPLOSION
•
Substitution of components may impair intrinsic safety / La substitution
des composants peut nuire à la sécurité intrinsèque.
•
To prevent ignition of flammable or combustible atmospheres, disconnect
power before servicing / Pour éviter l’inflammation d’atmosphères
inflammables ou combustibles, débranchez l’alimentation avant
l’entretien.
•
To reduce the risk of explosion, do not mix new batteries with used
batteries, or mix batteries from different manufacturers / Pour réduire le
risqué d’explosion, ne mélangez pas de piles neuves avec des piles
usages, or mélangez des piles de différents fabricants.
WARNING