I-40 Manual and Spark Ignition
www.lbwhite.com
Owner’s Manual • I-40
4
Specifications
(1) There are other factors that will affect the quantity of animals each heater can cover. These include building ventilation and control
systems, building insulation, building size and population density, etc. Consult your L.B. White dealer or call L.B. White for speci
fi
c
recommendations for your application.
(2) This is a typical sensor height range for poultry installations. The size and type of livestock being grown, heater spacing and height,
etc. will dictate sensor height. Care should always be taken to ensure that the sensor is suf
fi
ciently high as to not be damaged by
the animal during operation.
Maximum Input (btu/h)
40,000
Ventilation Air to Support Combustion (cfm)
468
Full Output Pressure (psig)
Butane / Propane
5
Manual Ignition Low Heat
Pressure (in. W.C.)
10-12
Heater Dimensions (in.) (See Fig. 1)
A
30 3/4
B
16
C
9 1/2
Fuel Consumption Per Hour
Butane / Propane
1.88
Animal Coverage Per Heater (1)
Chickens
2900-4400
Turkeys
920-1100
Recommended Height Installation for Livestock
from Point of Combustion Cone to Floor (ft.)
Chickens
6.5-7.5
Turkeys
5.5-6.5
Minimum Safe Clearances to
Combustible Materials (ft.)
Top of Hood to Ceiling
3
Point of combustion cone to
fl
oor
4.5
Sides
3
Animal Occupied Zone
Temperature Control Sensor
Location
Vertical from
fl
oor
6-12 in. (2)
Horizontal From Brooder
8-12 ft.