![L.B. White Foreman CI500 Owner'S Manual And Instructions Download Page 4](http://html.mh-extra.com/html/l-b-white/foreman-ci500/foreman-ci500_owners-manual-and-instructions_664882004.webp)
Foreman Ductable Dual Fuel Indirect-Fired Heater
www.lbwhite.com
Owner’s Manual • Foreman
4
Specifications
CI500
CI750
Fuel Type
L.P. Vapor
Withdrawal
Natural Gas
L.P. Vapor
Withdrawal
Natural Gas
Maximum Input (Btuh / kWh)
500,000 / 146.5
750,000 / 219.8
Inlet gas supply pressure
acceptable at the inlet of the
heater for purpose of input
adjustment (inches w.c. / kPa)
MAX. 13.5/3.36
MIN. 8.0/2.0
Burner manifold pressure
(inches w.c. / kPa)
3.9 / 0.97
5.7 / 1.42
2.8 / 0.70
3.4 / 0.85
Fuel Consumption per hour
23 Ibs. / 10.4 kg
500 ft3 / 14.2 m3
34.8 lbs. / 15.8 kg
750 ft.3 / 21.2 m3
Motor Characteristics
Ball Bearing, 1.5 H.P./
1,119 Watts, 1725 RPM
Ball Bearing, 2 HP / 1,119 Watts,
1725 RPM
Blower Speed (RPM)
1000
Electrical Supply (Volts / Hz /
Phased)
120 / 60 / 1
240 / 60 / 1
Amp Draw
Starting
35
Continuous
Operation
14.8
12.0
Dimensions (inches/cm)
L x W x H
92.5 x 32 x 44.5 / 235 x 81.3 x 113
Minimum Safe Distances From
Nearest Combustible Materials
(Feet/ Meter)
Top:
3.0 / 0.91
Sides:
1.0 / 0.30
Rear:
3.0 / 0.91
Blower Outlet:
6.0 / 1.83
Flue Pipe:
3.0 / 0.91
Propane Fuel Supply Container
U.S.
6.0 / 1.83
Canada
10.0 / 3.05
Minimum Ambient
Temperature in Which Heater
May be Used (°F/°C)
-20 / -29