Connection to LA amplied controllers
Cabling
Accessory
connector sealing plate (provided)
Screws and fasteners
4 x M5x16 screws (provided)
Tools
torque screwdriver
T25 Torx bit
small tool or at screwdriver (3 mm or less)
Min number of operators
1
Assembly
Prerequisite
The cable glands on the connector sealing plates are compatible with cables up to 4 × 4 mm
2
gauge.
Refer to:
•
APPENDIX A: Recommendation for speaker cables
(p.83)
•
(p.63)
About this task
The connector sealing plates have two cable glands: one for the input cable and one for the cable connecting to the next
enclosure in parallel. The second cable gland is equipped with a protective plug.
This procedure describes how to connect the input cable to the enclosure. If the enclosure must be connected in parallel,
remove the protective plug from the second cable gland and proceed identically for both cables.
Procedure
1.
On the connector sealing plate, remove the sealing nut from the cable gland.
64
K3i owner's manual (EN) version 1.0