Rigging procedures
Procedure
1.
Secure K3i-CEILINGBRACKET to the ceiling using four M10 screws and fasteners.
Fasteners for ceiling-mounting.
Select screw length and anchors applicable to the ceiling properties.
Model the array in Soundvision and check the loads on rigging in the
Mechanics
view.
The ceiling holes are the centered hole (on the shorter side).
984 mm / 38.7 in
Ø11.5 mm / 0.43 in
32
2.
2
m
m
/ 1
2.
7
in
2.
On the rst enclosure, remove the relevant placeholder screws on both sides.
A
C
B
C
B
A
Risk of acoustic leaks
Do not remove the placeholder screws from the bottom rear inserts (A, B or C) that are not used.
rigging accessory
inter-element angles
used insert
0.25°, 3°
C
2°, 5°, 10°
B
K3i-LINK (connecting from an
enclosure below) / KARAIIi-
DOWNK3i
1°, 4°, 7.5°
A
K3i-RIGBAR
—
B
K3i-TILTBRACKET
5°, 2.5°, 0°, -2.5°, -5°, -7.5°, -10°, -12.5°, -15°
A
It is recommended to use the rigging report from Soundvision to prepare the enclosures.