200
Case
8.
Movement stops suddenly during playing/operation
・Battery is running out?
Normal Operating time of MANOI PF01 is 30〜40 mins(depends on type of playing Motion,
or condition such as temprature). When Battery is running out, Controll Board can not
get enough current, and it could produce improper operating signals. Change to
full‑charged battries, or re‑charge batteries.(See: Operation 1‑1)
Even using full‑charged battries, situation does not change, it could be protecting
circuit working by some reasons. Turn Power Switch OFF and remove all batteries,
then disassemble mainly joint part where there is a large concentration of Servo
Leads such as Shoulders or Hip to check if coating of Servo Lead is broken or Servo
Lead is bent with sharp angle. If any problem is found with Servo Lead, remove
it and replace new Servo Lead.
If there is no case as avove and has same problem, contact the store where you
purchased MANOI.