安
全
の
た
め
の
注
意
事
項
付
属
製
品
に
つ
い
て
組
み
立
て
ソ
フ
ト
ウ
ェ
ア
の
設
定
M
A
N
O
I
で
の
遊
び
方
オ
プ
シ
ョ
ン
パ
ー
ツ
の
取
り
付
け
故
障
か
な
と
思
っ
た
ら
ユ
ー
ザ
ー
相
談
室
の
ご
案
内
用
語
集
パ
ー
ツ
販
売
リ
ス
ト
展
開
図
199
・
CH Label of Servo Lead and CH of Control Board where Servo Lead is inserted is correct?
→Check CH Label of Servo Lead and CH of Control Board where Servo Lead is inserted.
(See: Operation 8‑3)
・Battery is running out?
・
Assigment of button is doen correctly
?
Radio Control(Wirelss Control) by using Radio Control Unit USB(Option from KONDO KAGAKU)
and KRT‑1(Option from KONDO KAGAKU), it is necessary that signal from Operation Button
and number which is set for Motion should be same. (See: Operation OP01)
Case
5.
Abnormal noise on Movement
・There is friction of Flame in range of movement or there is unresonable lord?
?
→Sample Motions are not supposed to cause abnormal noice or friction of flames.
Check setting of Home Position again.(See:Operation S3‑1)
→Even setting of Home Positon is done, situation does not change, there may be some
problem on method of Assembling. Disassemble parts of pertinent part and set nutral
point of Servo Motor(See: Operation 2‑4), then re‑assemble pertinent part.
・Abnormal noise is from Servo Motor of joint?
→There is possiblity of that gear in Servo motor is broken. Stop operationg and
conatct the store where you purchased MANOI.
Case
6.
Sound like Geee never stops
・
There is sould/noise like Geeeee even no movement or no operation, it is sound of Servo
Motor keeps position of joints. It is not problem.
Case
7.
Abnormal odor
・Smoking?
→If there is smoking from MANOI PF01, stop playing/operating immidiately and turn
Power OFF. Then, contact the store where you purchased MANNOI.
・Abnormal odor is from paint of surface or Rubber parts?
→There is remaining volatilization component which is included in paint or some material.
Store MANOI at indoor airy place and avoiding direct sunlight, it will disappear in
a week normally.
Normal Operating time of MANOI PF01 is 30〜40 mins(depends on type of playing Motion,
or condition such as temprature). When Battery is running out, Controll Board can not
get enough current, and it could produce improper operating signals. Change to
full‑charged battries, or re‑charge batteries.(See: Operation 1‑1)
Summary of Contents for Manoi Athlete Humanoid Series
Page 37: ...206 M A N O IT M P F 01 Exploded View...
Page 38: ...MANOI 207 Expanding View 1...
Page 39: ...208 Expanding View 2...
Page 40: ...MANOI 209 Expanding View 3...
Page 41: ...210 Expanding View 4...