2FB/2FC-2.0
2-3-35
YC5
A1
24V
I
24 V DC
24 V DC power input
Connected
to the MP
tray unit
A2
MP SOL PUL
O
0/24 V DC
MP solenoid (activate): On/off
A3
MP SOL RTN
O
0/24 V DC
MP solenoid (return): On/off
A4
5V
O
5 V DC
5 V DC power output
A5
MP PE SW
I
0/5 V DC
MP paper empty switch: On/off
A6
SGND
-
-
Signal ground
A7
5V
O
5 V DC
5 V DC power output
A8
CONT SENS
I
Analog
Toner container detection signal
A9
SGND
-
-
Signal ground
B1
SGND
-
-
Signal ground
B2
MP DIG2
I
0/5 V DC
MP paper width size switch: On/off
B3
MP DIG1
I
0/5 V DC
MP paper width size switch: On/off
B4
MP DIG0
I
0/5 V DC
MP paper width size switch: On/off
B5
MP PSD SW
I
0/5 V DC
MP paper length size switch: On/off
B6
SGND
-
-
Signal ground
B7
SGND
-
-
Signal ground
B8
MP TRY SW
I
0/5 V DC
MP tray switch: On/off
B9
5V
O
5 V DC
5 V DC power output
YC6
1
MP MOT/A
O
0/24 V DC
(pulse)
MP feed motor drive signal
Connected
to the MP
feed motor,
toner motor
and toner
container
detection
switch
2
24V
O
24 V DC
24 V DC power output
3
MP MOT A
O
0/24 V DC
(pulse)
MP feed motor drive signal
4
MP MOT B
O
0/24 V DC
(pulse)
MP feed motor drive signal
5
24V
O
24 V DC
24 V DC power output
6
MP MOT/B
O
0/24 V DC
(pulse)
MP feed motor drive signal
7
TONER MOT/B
O
0/24 V DC
(pulse)
Toner motor drive signal
8
TONER MOT/A
O
0/24 V DC
(pulse)
Toner motor drive signal
9
TONER MOT B
O
0/24 V DC
(pulse)
Toner motor drive signal
10
TONER MOT A
O
0/24 V DC
(pulse)
Toner motor drive signal
11
SGND
-
-
Signal ground
12
CONTENA SET
I
0/5 V DC
Toner container detection switch: On/off
13
N.C
-
-
Not used
14
N.C
-
-
Not used
YC7
A1
SGND
-
-
Signal ground
Connected
to the deck
conveying
unit
A2
LCF SW B
I
0/5 V DC
Deck conveying switch 2: On/off
A3
5V
O
5 V DC
5 V DC power output
A4
SGND
-
-
Signal ground
A5
LCF SW A
I
0/5 V DC
Deck conveying switch 1: On/off
A6
5V
O
5 V DC
5 V DC power output
A7
SGND
-
-
Signal ground
A8
LCF SET
I
0/5 V DC
Deck conveying unit set signal
A9
SGND
-
-
Signal ground
A10
N.C
-
-
Not used
A11
5V
O
5 V DC
5 V DC power output
A12
LCF SW A1
I
0/5 V DC
Timing switch 1: On/off
B1
SGND
-
-
Signal ground
B2
LIM SW1
I
0/5 V DC
Lift limit switch 1: On/off
B3
5V
O
5 V DC
5 V DC power output
B4
SGND
-
-
Signal ground
B5
PE SW1
I
0/5 V DC
Paper empty switch 1: On/off
Connector
Pin No.
Signal
I/O
Voltage
Description
Summary of Contents for KM-6030
Page 1: ...SERVICE MANUAL Published in March 2006 842FB114 Rev 4 KM 6030 KM 8030...
Page 4: ...This page is intentionally left blank...
Page 10: ......
Page 82: ...2FB 2FC 2 0 1 4 13 This page is intentionally left blank...
Page 90: ...2FB 2FC 3 1 4 19 This page is intentionally left blank...
Page 110: ...2FB 2FC 3 1 4 37 This page is intentionally left blank...
Page 184: ...2FB 2FC 4 1 5 25 This page is intentionally left blank...
Page 267: ...2FB 2FC 3 1 6 30 This page is intentionally left blank...
Page 288: ...2FB 2FC 4 1 6 51 This page is intentionally left blank...
Page 323: ...2FB 2FC 2 0 1 6 84 This page is intentionally left blank...
Page 463: ......