2FB/2FC-3
1-4-39
U194
Setting the fuser web drive
Description
Sets the interval (number of copies) for turning on the fuser web solenoid.
Purpose
To be executed when the fuser web roller becomes extremely soiled.
Method
Press the start key. The screen for adjustment is displayed.
Setting
1. Change the setting using the cursor up/down keys.
When setting to the value above default setting, replacement is needed before 500000.
2. Press the start key. The value is set.
Completion
To exit this maintenance item without changing the current value, press the stop/clear key.
The screen for selecting a maintenance item No. is displayed.
U196
Turning the fuser heater on
Description
Turns the fuser heater M, S or L on.
Purpose
To check fuser heater turning on.
Method
1. Press the start key. The screen for selecting an item is displayed.
2. Select the heater to be turned on. The selected heater turns on for 2 s and then turns off.
Completion
Press the stop/clear key when fuser heater M, S and L are off.
The screen for selecting the maintenance item No. is displayed.
U198
Setting the fuser phase control
Description
Sets the use of fuser phase control.
Purpose
Normally no change is necessary.
If voltage descent accompanying fuser heater lighting occurs, select fuser phase control.
Method
Press the start key. The screen for adjustment is displayed.
Setting
1. Select ON or OFF. The selected item is displayed in reverse.
Initial setting: ON (220-240 V specifications) / OFF (120 V specifications)
2. Press the start key. The value is set, and the maintenance mode is exited.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key.
The screen for selecting a maintenance item No. is displayed.
Maintenance
item No.
Description
Setting
Setting range
Default setting
Interval for turning on the fuser web solenoid
0 to 255
30 (sheets)
Display
Description
FIX HEAT M
Fuser heater M (FH-M)
FIX HEAT S
Fuser heater S (FH-S)
FIX HEAT L
Fuser heater L (FH-L)
Display
Description
ON
Fuser phase control present
OFF
Fuser phase control absent
Summary of Contents for KM-6030
Page 1: ...SERVICE MANUAL Published in March 2006 842FB114 Rev 4 KM 6030 KM 8030...
Page 4: ...This page is intentionally left blank...
Page 10: ......
Page 82: ...2FB 2FC 2 0 1 4 13 This page is intentionally left blank...
Page 90: ...2FB 2FC 3 1 4 19 This page is intentionally left blank...
Page 110: ...2FB 2FC 3 1 4 37 This page is intentionally left blank...
Page 184: ...2FB 2FC 4 1 5 25 This page is intentionally left blank...
Page 267: ...2FB 2FC 3 1 6 30 This page is intentionally left blank...
Page 288: ...2FB 2FC 4 1 6 51 This page is intentionally left blank...
Page 323: ...2FB 2FC 2 0 1 6 84 This page is intentionally left blank...
Page 463: ......