Maintenance
5-7
4
Place the drum unit flat on a clean, level surface.
5
Use a clean, lint free cloth to clean dust and dirt away from the metal
registration roller.
6
On the drum unit, slide the charger cleaner (green) back and forth 2
or 3 times to clean the charger wire, then return it to its original
position (CLEANER HOME POSITION).
7
When cleaning is complete, return the drum unit to the original
position.
IMPORTANT Do not place the drum unit on end.
IMPORTANT Take care not to touch the transfer roller (black)
during cleaning.
IMPORTANT Remove the fixing tape on the charger cleaner in
case of the first cleaning.
After cleaning, make sure you restore the charger cleaner to its
home position.