ORIGINAL OPERATING INSTRUCTIONS
Commissioning
25.04.2019
27/54
Hinweis
For the correct configuration of the drive signal, the carrier vehicle must fulfill the
following conditions:
•
The drive signal must have been taken correctly from the carrier vehicle
•
Square wave signal
•
Pulse-Pause max. 20%
•
min. 4 imp/min.
•
Voltage swing min. 4 V
•
max. 1kHz
1
Start setup menu (see Chapter
7.2 "Start/finish setup menu", page 25
).
2
Actuate several times.
➯
➯
3
Depending on carrier vehicle drive either 15 km/h or 30 km/h (30 km/h is
preferable).
Hinweis
■
V15 = the control system is taught when the carrier vehicle drives at a speed of
15 km/h.
■
V30 = the control system is taught when the carrier vehicle drives at a speed of 30
km/h.
4
Start driving until the speedometer of the carrier vehicle shows the set speed.
5
Press shortly as soon as the
speed has been reached.