![Kubota M6H-101 Operator'S Manual Download Page 185](http://html1.mh-extra.com/html/kubota/m6h-101/m6h-101_operators-manual_2008852185.webp)
When this circulation has ended, do the
replacement job. During cooling, the fluid's
circulating noise is heard.
• Do not apply oil to the o-ring of the filter.
M6L-111
1. Place a stand under the DEF/AdBlue
®
tank unit.
2. Remove 3 nuts from the underside and 2 bolts from
the top side of the tank unit.
3. Move the unit by pushing the stand forward to
reveal the DEF/AdBlue
®
pump cover.
4. Remove 2 bolts and then remove the pump cover.
(1) DEF/AdBlue
®
tank unit
(2) Nut
(3) Bolt
(A) “MOVE”
5. Clean around the plug and remove the plug.
6. Loosen the top of the filter assembly and remove it
from the pump.
7. Replace the filter assembly with a new one.
(1) Filter assembly
(2) Plug
(3) O-ring
(4) DEF/AdBlue
®
pump
(5) DEF/AdBlue
®
tank
NOTE :
• Even after stopping the engine, the injector
cooling DEF/AdBlue
®
fluid continues to
circulate through the circuit for a couple of
minutes.
When this circulation has ended, do the
replacement job. During cooling, the fluid's
circulating noise is heard.
• Do not apply oil to the o-ring of the filter.
M6H-101
1. Remove 2 bolts from the underside and 4 bolts
from the lateral side, and then remove the DEF/
AdBlue
®
tank cover.
EVERY 3000 HOURS
PERIODIC SERVICE
M6S-111,M6L-111,M6H-101
179
Summary of Contents for M6H-101
Page 6: ......
Page 14: ...8 M6S 111 M6L 111 M6H 101 ...
Page 23: ...SAFETY LABELS SAFE OPERATION M6S 111 M6L 111 M6H 101 17 ...
Page 24: ...SAFE OPERATION 18 M6S 111 M6L 111 M6H 101 ...
Page 25: ...SAFE OPERATION M6S 111 M6L 111 M6H 101 19 ...
Page 26: ...SAFE OPERATION 20 M6S 111 M6L 111 M6H 101 ...
Page 27: ...SAFE OPERATION M6S 111 M6L 111 M6H 101 21 ...
Page 28: ...SAFE OPERATION 22 M6S 111 M6L 111 M6H 101 ...
Page 30: ...24 M6S 111 M6L 111 M6H 101 ...