6-S1
GR1600EC2, WSM
ELECTRICAL SYSTEM
1. TROUBLESHOOTING
W1014322
BATTERY
W1013718
Symptom
Probable Cause
Solution
Reference
Page
All Electrical
Equipments Do Not
Operate
Battery discharged or defective
Recharge or replace
G-24,
1-S19
Battery positive cable disconnected or
improperly connected
Repair or replace
–
Battery negative cable disconnected or
improperly connected
Repair or replace
–
Slow blow fuse blown (40 A)
Replace
G-35
Fuse Blown
Frequently
Short-circuited
Repair or replace
–
Battery Discharges
Too Quickly
Battery defective
Replace
1-S19
Dynamo defective
Repair or replace
6-S21
Regulator defective
Replace
6-S15, 16
Wiring harness disconnected or improperly
connected (between battery positive terminal
and regulator B terminal)
Repair or replace
–
Cooling fan belt slipping
Adjust tension
G-28
KiSC issued 07, 2006 A
Summary of Contents for GR1600EC2
Page 1: ...GR1600EC2 WORKSHOP MANUAL KiSC issued 07 2006 A...
Page 7: ...5 GR1600EC2 WSM SAFETY INSTRUCTIONS KiSC issued 07 2006 A...
Page 8: ...6 GR1600EC2 WSM SAFETY INSTRUCTIONS KiSC issued 07 2006 A...
Page 11: ...9 GR1600EC2 WSM DIMENSIONS DIMENSIONS KiSC issued 07 2006 A...
Page 12: ...G GENERAL KiSC issued 07 2006 A...
Page 61: ...1 ENGINE KiSC issued 07 2006 A...
Page 118: ...2 TRANSAXLE KiSC issued 07 2006 A...
Page 164: ...3 BRAKES KiSC issued 07 2006 A...
Page 174: ...4 FRONT AXLE KiSC issued 07 2006 A...
Page 182: ...5 STEERING KiSC issued 07 2006 A...
Page 192: ...6 ELECTRICAL SYSTEM KiSC issued 07 2006 A...
Page 224: ...7 MOWER KiSC issued 07 2006 A...
Page 225: ...CONTENTS MECHANISM 1 POWER TRANSMISSION 7 M1 2 LIFTING MECHANISM 7 M2 KiSC issued 07 2006 A...