Limes LA50 / BA5
Absolute Magnetic Length Measurement System
Magnetic tape length = measuring sensor length
The best installation location for the magnetic tape is in a groove or against an edge.
Stick the tape in place as follows:
The magnetic tape and the steel tape have been assembled already at the factory. The adhe-
sive tape is applied on the carrier side (steel tape). Now position the magnetic tape and stick
it in place. The easiest is to stick the magnetic tape in two steps. First remove the protective
foil up to the half and stick the tape in place, then remove the remaining length. Finally, stick
the cover tape on the visible dark brown magnetised plastic tape.
6.3 Mounting / Installation of the Sensor
NOTICE!
The correct distance sensor / magnetic tape is monitored and displayed by
the LED on the sensor.
-> Distance not correct = LED glow red
When installing the sensor head use two M3 screws. Tolerances for distance and angle must
be observed.
Dimensions in mm [inch]
Distance sensor / magnetic band (incl. masking tape)
Tilting
Torsion
Offset
± 0,5°
± 0,5°
± 0,5°
0,1 ... 1,
5
[0.004 ... 0.06
]
± 0,5
[± 0.02
]
L
50 [1.97]
50 [1.97]
± 0,5°
± 0,5°
± 0,5°
0,1 ... 1,
5
[0.004 ... 0.06
]
± 0,5
[± 0.02
]
L
50 [1.97]
50 [1.97]