EN 33/38
English
Manual
Limes LA50 / BA5
Absolute Magnetic Length Measurement System
7.5 Offset
After the installation of the magnetic tape and the measuring system (sensor head), a value is
transmit by the interface. Because this value does not conform to the machine zero point, an
offset should to be deposited at the controller side.
NOTICE!
An offset is necessary in each case of a replacement of the EMAX encoder
(sensor head) or magnetic tape.
7.6 Pin Connections
7.6.1 SSI- and CANopen Interface
Pin Connection SSI-Interface Cable 1
Signal cable
SSI
CAN
White
0V/GND
0V/GND
Brown
+10-30 VDC
+ 10-30 VDC
Yellow
D +
CAN high
Orange
D -
CAN low
Green
C +
–
Violet
C -
–
Grey
–
–
Black
–
–
Shield
PE*
PE*
*) Connect shield only at the device!
Position of the switch:
Termination impedance: OFF
Position of the switch:
Termination impedance: ON