EN 13/38
English
Manual
Limes LA50 / BA5
Absolute Magnetic Length Measurement System
SSI interface
CANopen interface
Output driver
RS485 transceiver type
Permissible load / channel
max. 20 mA
Signal level
HIGH typ. 3.8 V
LOW at I
Load
= 20 mA typ. 1.3 V
Clock rate
25 bit (24 + 1 failurebit for distance)
Code
Binär / Gray (Default) switchable
SSI clock rate
80 kHz ... 0.4 MHz
Monoflop time
≤
40 µs
Data refresh rate
≤
250 µs
Interface
CAN High-Speed acc. to ISO 11898,
Basic and Full CAN, CAN specification 2.0 B
Protocol
CANopen
Baud rate
250 kbit/s; 125 ... 1000 kbit/s configurable
Termination
yes/no via rotary switch
Node address
1 ... 15 configurable (Default 1)
LSS protocol
CIA LSS protocol DS305
Global command support for node address and baud rate,
Selective commands via attributes of the identity object.