R60723.0002
–
Index
6c
EN
‐
page
26
/
62
Continuation
„
Mode
Process
Time
“:
WAIT
TIME
(S)
This
parameter
defines
the
period
time
of
the
lowest
frequency,
accordingly
the
time
between
two
rising
signal
edges
detecting
frequency
0
Hz.
Frequencies
with
a
period
time
higher
than
the
set
“WAIT
TIME”
will
be
detected
as
frequency
=
0
Hz.
0.01
Frequency
=
0
Hz,
for
frequencies
below
100
Hz
1.00
Default
value
80.00
Frequency
=
0
Hz,
for
frequencies
below
0,01
Hz
STANDSTILL
TIME
(S)
This
parameter
defines
the
time
setting
for
standstill
definition.
A
time
of
xx.xx
seconds
after
detection
"
frequency
=
0
Hz
"
the
unit
signals
"standstill"
and
reactivates
the
start
‐
up
‐
delays.
Stand
still
detection
can
be
set
in
PRESELECT
MENU.
0.00
Shortest
time
…
99.99
Longest
time
AVERAGE
FILTER
Selectable
average
or
filter
function
to
avoid
measuring
fluctuations
by
unstable
frequencies.
At
setting
1
to
4
a
floating
average
calculation
is
performed.
At
settings
5
to
8,
the
device
uses
an
exponential
filter.
The
time
constant
T
(63%)
corresponds
to
the
sampling
cycles.
For
example:
If
SAMPLING
TIME
=
0,1
s
and
AVERAGE
FILTER
=
Exponential
filter,
T
(63
%)
=
2x
SAMPLING
TIME,
after
0,2
seconds,
63%
of
the
step
size
are
reached
0
No
average
value
will
be
created
1
2
numbers
of
floating
average
cycles
2
4
numbers
of
floating
average
cycles
3
8
numbers
of
floating
average
cycles
4
16
numbers
of
floating
average
cycles
5
Exponential
filter,
T
(63
%)
=
2x
SAMPLING
TIME
6
Exponential
filter,
T
(63
%)
=
4x
SAMPLING
TIME
7
Exponential
filter,
T
(63
%)
=
8x
SAMPLING
TIME
8
Exponential
filter,
T
(63
%)
=
16x
SAMPLING
TIME