R60723.0002
–
Index
6c
EN
‐
page
30
/
62
Continuation
„
Mode
Counter
“:
BATCH
/
TOTAL
MODE
Setting
of
the
batch
counter
/
total
counter.
The
function
of
batch
counting
according
to
a
preset
value
is
only
possible
in
combination
with
the
switch
condition
“automatic
reset
to
zero”
(RESULT
<=
PRES
‐
>
0),
“automatic
reset
to
set
value
(RESULT>=PRES
‐
>VALUE)
or
“set
the
counter
value”
(RESULT
<=0
‐
>
SET).
When
BATCH
/
TOTAL
MODE
is
active,
PRESELECTION
serves
as
the
present
value
(SOURCE
1
‐
4)
for
the
BATCH
COUNTER
or
the
TOTAL
COUNTER.
Example
for
the
batch
counter:
If
the
batch
counter
should
increment
1
all
1000
pulses,
the
value
e.g.
PRESELCTION
1
has
to
be
set
to
1000,
the
related
reference
source
SOURCE
1
to
“MEASUREM.
RESULT”,
the
corresponding
switching
condition
MODE
1
to
"RESULT>=PRES
‐
>0"
and
BATCH
/
TOTAL
MODE
to
INCREMENT
BATCH.
Should
an
output
be
turned
on
after
a
batch
amount
of
33,
e.g.
PRESELECTION
2
has
to
be
set
to
33,
the
related
reference
source
SOURCE
2
to
“BATCH
COUNTER”
and
the
switching
condition
of
MODE
2
has
to
be
set
to
display
value
greater
than
or
equal
(RESUL>=PRES).
Example
for
the
total
counter:
For
the
total
counter,
BATCH
/
TOTAL
MODE
must
be
set
to
TOTAL
COUNTER.
The
total
counter
counts
here
parallel
to
the
main
counter.
e.g.
If
the
total
counter
should
automatically
reset
to
0,
when
4000
is
reached,
the
preset
value
e.g.
PRESELECTION
3
must
be
set
to
“4000”,
the
reference
source
SOURCE
3
must
be
set
to
“TOTAL
COUNTER”
and
the
corresponding
switching
condition
MODE
3
must
be
set
to
"RESULT>
=
PRES
‐
>
0"
0
OFF
No
batch
counter
and
no
total
counter
1
INCREMENT
BATCH
increment
batch
counter
2
DECREMENT
BATCH
decrement
batch
counter
3
USE
INPUTS
ONLY
increment
/
decrement
batch
counter
only
by
external
commands
(see
command
menu)
4
TOTAL
COUNTER
Total
counter
is
activated
BATCH
/
TOTAL
SET
VALUE
In
case
of
a
reset/set
command
(„SET
BATCH
/
TOTAL“
via
control
input)
the
batch
counter
/
total
counter
is
set
to
the
BATCH
/
TOTAL
SET
VALUE.
The
parameter
is
only
visible
when
BATCH
/
TOTAL
MODE
is
active.
0
Smallest
value
…
99999999
Highest
value
ROUND
LOOP
VALUE
Defines
the
number
of
steps
when
a
round
‐
loop
function
is
desired.
(Round
‐
loop
function
only
for
COUNT
MODE:
„A
SINGLE“
or
„A/B
90
x
X“)
0
Normal
display
without
round
‐
loop
function
…
99999999
Number
of
steps
for
the
round
‐
loop
function