R60723.0002
–
Index
6c
EN
‐
page
28
/
62
Continuation
„
Mode
Timer
“:
INC
/
DEC
MODE
When
START/STOP
is
setting
to
period
time
measurement,
the
time
measurement
works
always
adding.
0
INCREMENT
MODE
time
measurement
works
adding
1
DECREMENT
MODE
time
measurement
works
subtracting
TOTAL
TIME
MODE
Setting
of
the
total
timer
(total
time
measurement).
When
TOTAL
TIME
MODE
is
active,
PRESELECTION
serves
as
the
preset
value
for
the
total
timer.
Example:
For
the
total
time
measurement
TOTAL
TIME
MODE
has
to
be
set
to
YES.
The
total
time
measurement
runs
parallel
to
the
normal
time
measurement.
If
the
total
time
measurement
should
be
automatically
reset
to
O
when
1:30
(H:M)
is
reached,
the
reference
source
must
be
set
e.
g.
to
“SOURCE1”from
the
corresponding
preselection
menu
to
“TOTAL
TIMER”,
the
corresponding
preset
value
e.
g.
“PRESELECTION
1”
to
“1:30”
and
the
corresponding
switching
condition
“MODE1”
to"RESULT>
=
PRES
‐
>
0"
0
NO
No
total
time
measurement
1
YES
Total
time
measurement
activated
TOTAL
TIME
SET
VALUE
With
a
reset/set
command
(command
„SET
TOTAL
TIME“
via
control
input)
the
total
timer
(total
time
measurement)
is
set
to
the
value
entered
here.
The
parameter
is
only
visible
when
TOTAL
TIME
MODE
is
active.
0
Smallest
value
(reset)
…
99999999
Highest
value