R60723.0002
–
Index
6c
EN
‐
page
8
/
62
3
Electrical
Connections
The
terminal
screws
should
be
tightened
with
a
slotted
screwdriver
(blade
width
2mm).
6.571T.XXX.X0X
6.571T.XXX.XAX
3.1
DC
Power
Supply
The
unit
accepts
DC
supply
from
18
to
30
V
at
the
terminals
1
and
2.
The
power
consumption
depends
on
the
level
of
the
supply
voltage
with
approx.
100
mA
and
the
additional
current
required
at
the
Auxiliary
Voltage
Output.
All
GND
terminals
are
internally
interconnected.
3.2
Auxiliary
Voltage
Output
Terminal
3
and
4
provide
an
auxiliary
output
for
supply
of
sensors
and
encoders.
The
output
voltage
depends
on
the
power
supply.
DC
version
AC
version
The
encoder
voltage
is
approx.
1
V
lower
than
the
power
supply
voltage
at
terminal
1
and
2
and
should
be
loaded
with
max.
250
mA.
The
encoder
voltage
is
24
VDC
(±
15%)
and
should
be
loaded
with
max.
150
mA
up
to
45
degrees
Celsius.
At
higher
temperature
the
maximum
output
current
is
reduced
to
80
mA.
At
6.571T.XXX.XAX
devices,
the
auxiliary
voltages
output
is
switchable
from
24
VDC
to
5
VDC.