5.1
General
Menu
OPERATIONAL
MODE
This
parameter
specifies
the
selected
measuring
function.
0
SPEED
Speed
indicator
(RPM),
tachometer
or
frequency
counter
1
PROCESS
TIME
Operation
as
baking
time
or
processing
time
indicator
(reciprocal
speed)
2
TIMER
Operation
as
stopwatch
3
COUNTER
Operation
as
position
indicator,
event
‐
,
sum
‐
,
differential
‐
or
up
‐
down
counter
4
VELOCITY
Runtime
measurement
as
speed
indicator
ENCODER
PROPERTIES
(for
6.571T.XXX.X0X)
This
parameter
determines
the
characteristics
of
the
pulse
input
for
6.571T.XXX.X0X.
0
PNP
PNP
(switch
to
+)
1
NPN
NPN
(switch
to
‐
)
2
NAMUR
Connect
sensor
(–)
to
GND
and
sensor
(+)
to
input
(A
or
B)
3
TRI
‐
STATE
Tri
‐
State
for
push
‐
pull
encoders/
sensors
ENCODER
PROPERTIES
(for
6.571T.XXX.XAX)
This
parameter
determines
the
characteristics
of
the
pulse
input
for
6.571T.XXX.XAX.
0
RS422
RS422
standard
1
HTL
DIFFERENTIAL
HTL
differential
2
HTL
PNP
HTL
PNP
single
ended
(switch
to
+)
3
HTL
NPN
HTL
NPN
single
ended
(switch
to
‐
)
ENCODER
SUPPLY
(only
for
6.571T.XXX.XAX
available)
This
parameter
defines
the
voltage
of
the
auxiliary
supply
output
(Aux
‐
Out).
0
24VDC
SUPPLY
24
VDC
encoder
supply
1
5VDC
SUPPLY
5
VDC
encoder
supply
COUNTING
DIRECTION
This
parameter
determines
the
direction
of
counting
(only
in
mode
COUNTER).
0
FORWARD
forward
1
REVERSE
reverse