Section 6
Troubleshooting
72183219
4-2016/Rev 0
ORIGINAL INSTRUCTIONS
6-9
Short Component Life
Ensure all recommended service and maintenance procedures
Install all kit components at the same time, do not replace components individually
Verify all utility and pump installation requirements have been met
Common causes for excessively short component life include:
Poor inlet water quality
Low inlet water pressure
Improperly plumbed drain line
Improperly loaded tie rod(s)
Table 6-2
Short Component Life Guide
Malfunction
Indication
Comments
1.
Dynamic seal
Worn or damaged plungers
Install a Major Maintenance
Kit. See Section 5.
Worn or damaged check
valve assembly
Install a Minor Maintenance
Kit. See Section 5.
Worn or damaged dynamic
seal carrier
Install a Major Maintenance
Kit. See Section 5.
Inlet water temperature is too
high or too low
Call KMT Technical Services.
2.
Dynamic seal carrier
Worn or damaged plungers
Install a Major Maintenance
Kit. See Section 5.
Incorrect seal installation
Reinstall the dynamic seals.
Cooling ports in dynamic seal
carrier are clogged
Clean cooling ports.
Insufficient cooling water
flow
Inspect water filters and inlet
water supply pressure.