Section 5
Service Procedures
72183211
8-2016/Rev 01
ORIGINAL INSTRUCTIONS
5-14
Use care when removing the dynamic seal and rod seal. Do not scratch or nick the
seal carrier bore.
8.
Remove the subplate adapter. If necessary, use pry
bars or screwdrivers to remove the adapter.
9.
Remove the retaining ring from the adapter using snap
ring pliers.
10.
Remove the seal spacer and rod seal.
11.
Remove the two o-rings from the outer diameter of the
adapter.
12.
Discard the rod seal, o-rings and retaining ring. The
seal spacer will be reused.
13.
Place the end cap on a workbench vertically with the discharge check valve end up.
Figure 5-7: Discharge Check Valve Assembly Removal
14.
Position two flat screwdrivers in the circumferential groove in the outside diameter of the
check valve body and remove the check valve assembly from the end cap. Use care not to
damage the body or the end cap.
15.
Remove and retain the o-ring from the check valve body.
16.
Place the check valve body in the provided rebuild clamp.