04/SHOCK ABSORBER, SWINGARM
55
201091-10
–
Determine distance
between the floating piston and reservoir hole with the spe-
cial tool.
Depth micrometer (T107S) (
The floating piston is positioned in the lowermost position.
200267-10
–
When the vacuum gauge reaches the required value, turn control lever
Oil reser-
voir
to
Equalize pressure
.
Guideline
4 mbar
The pressure gauge increases to the required value.
0 bar
200268-10
–
When the pressure gauge reaches the required value, turn control lever
Damper
to
Pressure
.
Guideline
0 bar
Oil is pumped into the damper.
The pressure gauge increases to the required value.
3 bar
200269-10
–
When the pressure gauge reaches the required value, turn control lever
Damper
to
Vacuum
.
Guideline
3 bar
The pressure gauge drops to the required value.
0 bar
200270-10
–
When the pressure gauge reaches the required value, turn control lever
Oil reser-
voir
to
Vacuum
.
Guideline
0 bar
The vacuum gauge drops to the required value.
8 mbar
200267-10
–
When the vacuum gauge reaches the required value, turn control lever
Oil reser-
voir
to
Equalize Pressure
.
Guideline
8 mbar
The pressure gauge drops to the required value.
0 bar