5 Installation at Site
29 of 92
ILN / ILNC / ILNR
5211.8/08-EN
Size
Suction nozzle
Discharge nozzle
F
x
F
y
F
z
M
x
M
y
M
z
F
x
F
y
F
z
M
x
M
y
M
z
[N]
[N]
[N]
[Nm]
[Nm]
[Nm]
[N]
[N]
[N]
[Nm]
[Nm]
[Nm]
300-250-330
3350
3750
3000
2750
1900
2200
2800
3100
2500
1950
1300
1550
300-250-400
3355
3750
3015
2775
1900
2225
2790
3130
2530
1975
1325
1575
300-250-500
3355
3750
3015
2775
1900
2225
2790
3130
2530
1975
1325
1575
350-300-330
4000
3900
400
3100
2300
2600
3400
3100
3800
2200
2800
1950
350-300-400
3915
4365
3525
3625
2500
2925
3355
3750
3015
2775
1900
2225
350-300-500
3915
4365
3525
3625
2500
2925
3355
3750
3015
2775
1900
2225
500-400-430
4500
4100
4900
3600
4650
3150
4500
4100
4900
3600
4650
3150
5.4.3 Auxiliary connections
DANGER
Risk of potentially explosive atmosphere by incompatible fluids mixing in the
auxiliary piping
Risk of burns!
Explosion hazard!
▷
Make sure that the barrier fluid or quench liquid are compatible with the fluid
handled.
WARNING
Failure to use or incorrect use of auxiliary connections (e.g. barrier fluid, flushing
liquid, etc.)
Risk of injuries by escaping fluid!
Risk of burns!
Malfunction of the pump!
▷
Refer to the general arrangement drawing, the piping layout and pump
markings (if any) for the number, dimensions and locations of auxiliary
connections.
▷
Use the auxiliary connections provided.
▷
The connections must only be used to absorb stresses caused by the circulation
of the fluid handled. Do not expose the connections to any external stresses.
In the case of clean fluids handled no cooling liquid is required for the mechanical
seal. The mechanical seal is cooled by the circulation of the fluid handled.
NOTE
On pumps with a priming system a check valve must be fitted in the discharge line
immediately downstream of the pump.