5 Installation at Site
25 of 92
ILN / ILNC / ILNR
5211.8/08-EN
5 Installation at Site
5.1 Safety regulations
DANGER
Improper installation in potentially explosive atmospheres
Explosion hazard!
Damage to the pump set!
▷
Comply with the applicable local explosion protection regulations.
▷
Observe the information in the data sheet and on the name plates of pump and
motor.
NOTE
KSB can provide support for the selection of a piping system and foundation by
means of the required data and recommendations. However, the responsibility
regarding selection, installation and operation of these components lies with the
plant engineer or the corresponding companies commissioned.
5.2 Checks to be carried out prior to installation
Place of installation
WARNING
Installation on a mounting surface which is unsecured and cannot support the load
Personal injury and damage to property!
▷
Use a concrete of compressive strength class C12/15 which meets the
requirements of exposure class XC1 to EN 206-1.
▷
The mounting surface must be set, flat, and level.
▷
Check the indicated weights.
1. Check the structural requirements.
All structural work required must have been prepared in accordance with the
dimensions stated in the outline drawing/general arrangement drawing.
5.3 Installing the pump set
WARNING
Improper handling of mortar cartridge
Skin sensitisation and/or irritation!
▷
Wear suitable protective clothing.
WARNING
Impermissibly large inclination angle of the pump set
Personal injury and damage to property!
▷
Never exceed a maximum inclination angle of 15° off the vertical for single-
suction pumps mounted on a baseplate.