4 Description of the Pump (Set)
18 of 92
ILN / ILNC / ILNR
5211.8/08-EN
4.4 Name plate
KSB ITUR Spain, S.A.
Camino de Urteta, s/n
20800 Zarautz (Spain)
Mat.-No. 01533890 PC-02
ILNC 050-032-200 AGB I11D
9971XXXX56 00100/01
Q = 888.88 m³/ h
Ø 200 mm
H = 888.88 m
v = 3.4 mm²/s
n = 3500 rpm
2016
MEI ≥ 0,4
η --, - %
47132456
1
2
3
4
5
6
7
8
9
10
11
12
KSB ITUR Spain, S.A.
Camino de Urteta, s/n
20800 Zarautz (Spain)
Mat.-No. 01529956 PC-01
ILNC 050-032-200 AGB I11D
9971XXXX56 00100/01
Q = 888.88 m³/ h
Ø 200 mm
H = 888.88 m
v = 3.4 mm²/s
n = 3500 rpm
2016
47132456
COOLING WATER PUMP
13
a)
b)
Fig. 3:
Name plate (example) a) Standard b) Marine applications
1
Type series, size, version
2
Material number
3
KSB order number
4
Flow rate
5
Dynamic viscosity of the fluid
handled
6
Speed
7
Minimum efficiency index
8
Nominal impeller diameter
9
KSB order item number
10
Head
11
Year of construction
12
Efficiency
13
Customer-specific information
(optional)
4.5 Design
4.5.1 Design details ILN
Design
▪
In-line design
▪
Vertical installation
▪
Single-stage
▪
Single-suction or double-suction
4)
▪
Coupling between pump and motor
▪
Spacer bush (except 350-300-330 and 500-400-430)
Pump casing
▪
Radially split volute casing
▪
Volute casing with integrally cast pump feet
▪
Replaceable casing wear rings
Drive (fixed speed version)
▪
Surface-cooled IEC three-phase motor
▪
Type of construction IM V1
▪
Frequency 50 Hz/60 Hz
▪
Enclosure IP55
▪
230/400 V and 400/690 V
Shaft seal
▪
Mechanical seal
Impeller type
▪
Closed radial impeller
4
Double-suction design for sizes 350-300-330 and 500-400-430
Summary of Contents for ILN
Page 1: ...In line Pump ILN ILNC ILNR Operating Manual ...
Page 89: ...Index 89 of 92 ILN ILNC ILNR 5211 8 08 EN W Warnings 8 Warranty claims 7 ...
Page 90: ......