8 Servicing/Maintenance
50 of 64
Hya-Rain/Hya-Rain N
Fig. 42:
Connecting the power cable of the display panel (Hya-Rain N)
7. Insert the plate with pressure gauge and hose from the side.
Fig. 43:
Inserting the plate
8. Fit the mounting plate. Tighten the fastening screw hand-tight.
Fig. 44:
Fitting the mounting plate
9. Insert the control unit. Fasten it with the locking pin.
Fig. 45:
Inserting the control unit
10. Connect the suction line. Set the three-way valve to the corresponding position.
11. Connect and open the mains water supply and the discharge line.
12. Check the available mains voltage against the data on the name plate. Plug the
power plug into the socket.