4 Description
15 of 64
Hya-Rain/Hya-Rain N
4.4 Design details
Design
▪
Angled tank designed for wall mounting
▪
Mains water storage tank to EN 1717
– Material: PE-LLD, dark
– Storage volume approx. 13 l
▪
Float valve for mains water supply (approx. 2.7 m³/h)
▪
IP42 enclosure
Pump set
▪
230 V ± 10 %
▪
DOL starting
▪
Thermal class F
▪
Enclosure IP44
▪
Thermal motor protection with automatic reset and start-up
Bearings:
▪
Grease-packed deep groove ball bearings sealed for life
Electrical connection
▪
230 V, 50 Hz, 800 W
▪
Power input in stand-by mode: 2.5 - 3 Watt
▪
1.5 m power cable with shockproof plug