2 Safety
10 of 64
Evamatic-Box N
▪
Only use the lifting unit to handle the fluids described in the product literature
of the respective design variant.
▪
Never operate the lifting unit without the fluid to be handled
▪
Observe the minimum flow rates indicated in the data sheet or product literature
(to prevent overheating, bearing damage, etc).
▪
Observe the minimum flow rate and maximum flow rate indicated in the data
sheet or product literature (to prevent overheating, mechanical seal damage,
cavitation damage, bearing damage, etc).
▪
Do not throttle the flow rate on the inlet side of the lifting unit (to prevent
cavitation damage)
▪
Consult the manufacturer about any use or mode of operation not described in
the data sheet or product literature.
▪
Never exceed the permissible application and operating limits specified in the
data sheet or product literature regarding pressure, temperature, etc.
▪
Observe all safety information and instructions in this manual.