5 Installation at Site
26 of 64
Evamatic-Box N
NOTE
Pipe 710-1 measures 300 mm in length and is chamfered at both ends. This pipe is
especially designed to protrude from the collecting tank. Do not install this pipe
anywhere else in the piping system.
NOTE
Use special glue suitable for PVC for fitting and sealing the cylindrical parts.
1. Seal the pipe unions with Teflon tape or sealant.
2. Fit the parts and make sure they are correctly seated.
Check that the lift check valve is fitted for the correct direction of flow.
Observe the alignment of the discharge line protruding from the collecting tank
(alignment of elbow 13-18).