5 Installation at Site
27 of 64
Evamatic-Box N
5.4.1 Evamatic-Box N 200 l, transportable version
CAUTION
Superfluous sealant
Damage to the machinery!
Damage to the lift check valve!
▷
Do not use too much Teflon tape or sealant when sealing the lift check valve.
Fig. 6:
Installing the piping
1. Undo the screw which fastens the suction cover of the pump.
2. Fit three pump feet 182 at pump 655.
3. Seal male threaded fitting 720 and screw it to elbow 144.
4. Seal lift check valve 742 and screw it to male threaded fitting 720. Check that
the lift check valve is fitted for the correct direction of flow.
5. Seal threaded socket 731 and screw it to lift check valve 742.
6. Check that the joint ring has been fitted in the discharge nozzle. Fasten the pre-
assembled piping with screws 901-2, discs 550 and nuts 920 to the pump.
7. Fasten elbow 13-18 to pipe 710.2 and secure it with glue.
8. Fasten pipe adapter 730 to pipe 710.2 and secure it with glue.
9. Install outlet pipe 710-1 in the collecting tank. (
10. Position the pump together with the assembled piping in the collecting tank.
11. Fasten the pre-assembled piping consisting of elbow 13-18, pipe 710.2 and pipe
adapter 730 to outlet pipe 710-1 without using glue.
12. Accurately measure dimension A.