5 Installation at Site
29 of 64
Evamatic-Box N
5.4.2 Evamatic-Box N 200 l, stationary version (with Ama-Porter)
CAUTION
Superfluous sealant
Damage to the machinery!
Damage to the lift check valve!
▷
Do not use too much Teflon tape or sealant when sealing the lift check valve.
Fig. 8:
Installing the piping
1. Insert guide hoop 571 into the grooves provided for this purpose in flanged
bend 72-1.
2. Fasten flanged bend 72-1 with screws 901-2, discs 550 and nuts 920 to baseplate
890.
3. Seal elbow 144 and screw it to flanged bend 72-1.
4. Seal male threaded fitting 720 and screw it to elbow 144.
5. Seal lift check valve 742 and screw it to male threaded fitting 720. Check that
the lift check valve is fitted for the correct direction of flow.
6. Seal threaded socket 731 and screw it to lift check valve 742.
7. Fasten outlet pipe 710-1 to the collecting tank. (
8. Position the baseplate, flanged bend and pre-assembled piping in the collecting
tank. Make sure that the baseplate is positioned exactly on the protrusion
provided for this purpose. (
9. Fasten elbow 13-18 to outlet pipe 710-1 without using glue.
10. Accurately measure dimension A.