5 Installation at Site
20 of 62
Etanorm V
1228.87/01-EN
5 Installation at Site
5.1 Safety regulations
DANGER
Installing electric equipment (motors) in potentially explosive atmospheres
Risk of explosion!
▷
Comply with the applicable local explosion protection regulations.
▷
Verify the test certificate of the motor.
▷
Keep the test certificate close to the location of operation (e.g. in the foreman's
office).
5.2 Checks to be carried out prior to installation
Check the structural requirements.
The structural work required must have been prepared in accordance with the
dimensions stated in the outline drawing and/or general arrangement drawing.
5.3 Installing the pump set
Foundation
The sturdy cover plate 68-3.01 serves as a foundation on which the pump set is
fastened. This cover plate covers the tank opening completely. If the pump set is
supplied with cover plate and riser, the cover plate is supported by a sectional steel
frame provided on the tank.
If ordered without cover plate and riser, the pump set is supplied with a bolted-on
bracket 732. This bracket serves to mount the pump set on the tank.
If pump and motor are delivered separately, transport and installation can be
facilitated by screwing eyebolts into the threaded holes in the lantern for attaching
support ropes.
Installing the pump
1. Carefully align the support frame.
2. Align the base of the bracket.
3. Align the upper flange of the drive lantern with a spirit level.
4. Make adjustments between cover plate and tank edge, if required.
If the pump is installed without suction strainer, observe a minimum distance B
to the tank floor.
Summary of Contents for Etanorm V
Page 1: ...Vertical Low pressure Pump Etanorm V Design W Operating Manual ...
Page 60: ......
Page 61: ......