8 Trouble-shooting
52 of 62
Etanorm V
1228.87/01-EN
8 Trouble-shooting
WARNING
Improper work to remedy faults
Risk of injury!
▷
For any work performed to remedy faults, observe the relevant information
given in this operating manual and/or in the product literature provided by the
accessories manufacturer.
If problems occur that are not described in the following table, consultation with the
KSB service is required.
A
Pump delivers insufficient flow rate
B
Motor is overloaded
C
Increased bearing temperature
D
Vibrations during pump operation
Table 24:
Trouble-shooting
A B C D Possible cause
Remedy
11)
✘
-
-
- Pump delivers against an excessively high
pressure.
Re-adjust to duty point.
Fit a larger impeller.
✘
-
-
- Supply line or impeller clogged
Remove deposits in the pump and/or piping.
✘
-
-
✘
Suction lift is too high/NPSH
available
(positive
suction head) is too low.
Check/alter liquid level.
Check any strainers installed/suction opening.
✘
-
-
- Wrong direction of rotation
Interchange two of the phases of the power cable.
✘
-
-
- Speed is too low.
12)
Increase speed.
✘
-
-
✘
Wear of internal components
Replace worn components by new ones.
-
✘
-
✘
Pump back pressure is lower than specified in
the purchase order.
Re-adjust to duty point.
In the case of persistent overloading, turn down
impeller.
12)
-
✘
-
- Density or viscosity of fluid handled higher
than stated in purchase order
Contact KSB.
-
-
✘
- Increased axial thrust
12)
Clean balancing holes in the impeller.
Replace the casing wear rings.
-
-
✘ ✘
Defective motor deep groove ball bearing
Replace.
✘ ✘
-
- Motor is running on two phases only.
Replace the defective fuse.
Check the electric cable connections.
-
-
-
✘
Rotor out of balance
Clean the impeller.
Re-balance the impeller.
-
-
-
✘
Defective plain bearing
Replace.
-
-
-
✘
Flow rate is too low.
Increase the minimum flow rate.
11
Pump pressure must be released before attempting to remedy faults on parts which are subjected to pressure.
12
Contact KSB.