7 Servicing/Maintenance
44 of 62
Etanorm V
1228.87/01-EN
Spare parts set
Part No.
Description
211 - pump shaft
561.29
Grooved pin
914.24
Hexagon socket head cap screw
920.95
Nut
930.95
Safety device
940.01
Key
102 - volute casing
102
Volute casing
502.01
Casing wear ring
902.01
7)
Stud
903.01
Screw plug
903.03
Screw plug
920.01
7)
Nut
161 - casing cover
161
Casing cover
502.02
Casing wear ring
515 - locking ring
515
Locking ring
914.24
Hexagon socket head cap screw
381 - bearing cartridge
381.01
Bearing cartridge
412.24
O-ring
504
8)
Spacer ring
529.16
Bearing sleeve
550.80
9)
Disc
561.29
Grooved pin
932.41
9)
Circlip
932.42
10)
Circlip
341 - drive lantern
68-3.02
Cover plate
341
Drive lantern
902.11
Stud
920.11
Nut
7.7.4 Immersion depths
Table 20:
Symbols key
Symbol
Description
✓
Permissible immersion depth at rated speed
✓
(maximum speed)
Permissible immersion depth with PumpDrive (permissible maximum speed for operation
on a frequency inverter)
-
Combination impermissible
Table 21:
Overview of immersion depths for Etanorm V (2-pole)
Etanorm V
2 poles
Shaft unit
Motor
50 Hz
60 Hz
P
N
Immersion depth
P
N
Immersion depth
< 1000 mm
1000 mm
1250 mm
1500 mm
1750 mm
2000 mm
< 1000 mm
1000 mm
1250 mm
1500 mm
1750 mm
2000 mm
[kW]
(Maximum speed [rpm])
[kW]
(Maximum speed [rpm])
050-032-125.1
25
100L
3,0
✓
(3600)
✓
(3000)
✓
✓
✓
✓
3,45
✓
(3600)
✓
-
✓
✓
✓
050-032-125.1
25
132S
5,5
✓
(3600)
✓
(3000)
✓
-
✓
✓
6,3
✓
(3600)
✓
-
✓
✓
✓
050-032-125.1
25
112M
4,0
✓
(3600)
✓
(3000)
✓
✓
✓
✓
4,6
✓
(3600)
✓
-
✓
✓
✓
050-032-125.1
25
132S
7,5
✓
(3600)
✓
(3000)
✓
-
✓
✓
8,6
✓
(3600)
✓
-
✓
✓
✓
050-032-125
25
100L
3,0
✓
(3600)
✓
(3000)
✓
✓
✓
✓
3,45
✓
(3600)
✓
-
✓
✓
✓
7
For bolted casing cover only
8
Only for Etanorm V, in stainless steel, design W, shaft unit 55
9
Only for Etanorm V, in cast iron, design W, shaft unit 55
10
Only for Etanorm V, in cast iron, design W, shaft units 25, 35 and 55
Summary of Contents for Etanorm V
Page 1: ...Vertical Low pressure Pump Etanorm V Design W Operating Manual ...
Page 60: ......
Page 61: ......