4 Description of the Pump (Set)
18 of 62
Etanorm V
1228.87/01-EN
the shaft (6) enters the hydraulic system through the casing cover (10). The shaft runs
in rolling element bearings (2 and 3), which are supported by a motor housing (1)
linked with the pump casing and/or casing cover (10) via the support column (8) and
the drive lantern (4).
Sealing
The pump is seal-less with little leakage flowing into the support column (8) at the
shaft passage (9) and then through the overflow opening (7) back to the tank.
4.7 Noise characteristics
Table 6:
Surface sound pressure level L
pA
2)
Rated power input
P
N
[kW]
Pump set:
1450 rpm
[dB]
2900 rpm
[dB]
2,2
64
69
3,0
64
71
4,0
62
73
5,5
68
72
7,5
68
72
11,0
69
75
15,0
69
75
18,5
70
75
22,0
72
78
30,0
71
79
37,0
71
79
45,0
73
79
55,0
74
79
75,0
75
82
90,0
76
82
In wet installation, the pump itself does not contribute to sound emission levels.
4.8 Scope of supply
Depending on the model, the following items are included in the scope of supply:
▪
Pump
▪
Drive
▪
Cover plate
▪
Discharge line
4.9 Pump size / shaft unit combinations
Table 7:
Sizes with shaft unit WS 25
Size
Casing cover design
Clamped
Bolted
050-032-125.1
✘
-
050-032-160.1
✘
-
050-032-200.1
-
✘
050-032-250.1
-
✘
050-032-125
✘
-
050-032-160
✘
-
2
Surface sound pressure level to ISO 3744, valid for a pump operating range of Q/QBEP = 0.8 - 1.1 and non-
cavitating operation. If noise levels are to be guaranteed: Add +3 dB for measuring and constructional
tolerance.