6 Commissioning/Start-up/Shutdown
40 of 76
EtaLine Pro
1168.87/01-EN
Symbol
Description
Unit
H
Pump discharge head
m
T
f
Fluid temperature
°C
T
O
Temperature at the casing surface
°C
Pump efficiency at duty point
-
Temperature difference
K
6.2.3.2 Density of the fluid handled
CAUTION
Impermissibly high density of the fluid handled
Motor overload!
▷
Observe the information on fluid density in the data sheet.
The power input of the pump set will change in proportion to the density of the fluid
handled.
6.2.3.3 Abrasive fluids
Do not exceed the maximum permissible solids content specified in the data sheet.
When the pump handles fluids containing abrasive substances, increased wear of the
hydraulic system and shaft seal are to be expected. In this case, reduce the commonly
recommended inspection intervals.
6.2.4 Installation altitude
▪
≤ 1000 m above MSL, or 1 % power derating per additional 100 m
▪
Maximum installation altitude 2000 m above MSL
6.3 Shutdown/storage/preservation
6.3.1 Measures to be taken for shutdown
The pump (set) remains installed
ü
Sufficient fluid is supplied for the functional check run of the pump.
1. For prolonged shutdown periods, start up the pump (set) regularly between
once a month and once every three months for approximately five minutes.
ð
This will prevent the formation of deposits within the pump and the pump
intake area.
The pump (set) is removed from the pipe and stored
ü
The pump has been properly drained. (
ü
The safety instructions for dismantling the pump have been observed.
ü
The permissible ambient temperature for storing the pump is observed.
1. Spray-coat the inside wall of the pump casing and, in particular, the impeller
clearance areas with a preservative.
2. Spray the preservative through the suction nozzle and discharge nozzle.
It is advisable to then close the pump nozzles (e.g. with plastic caps)
3. Oil or grease all exposed machined parts and surfaces of the pump (with
silicone-free oil or grease, food-approved, if required) to protect them against
corrosion.
Observe the additional instructions on preservation.
If the pump set is to be stored temporarily, only preserve the wetted components
made of low-alloy materials. Commercially available preservatives can be used for
this purpose. Observe the manufacturer's instructions for application/removal.