7 Servicing/Maintenance
65 of 132
Amacan P
When dismantling the motor section and the power cable make sure that the cores/
terminals are clearly marked for future reassembly.
7.5.6.1 Removing the motor housing cover
571
812
903.51
914.01
81-2
835/
185
A
A
A-A
Fig. 37:
Removing the motor housing cover
ü
Suitable lifting equipment is on hand.
ü
The pump set has been disconnected from the power supply. It has been securely
placed on a level surface in a vertical position.
1. Attach lifting equipment to eyebolt 900.04 or bail 571.
2. Undo hexagon socket head cap screws 914.01.
3. Carefully lift off motor housing cover 812. If the motor housing cover cannot be
lifted off, use the extraction threads located underneath caps 903.51.
4. Remove the cable ties.
5. Lift motor housing cover 812 up further until the power cables and control cable
can be disconnected.
6. Disconnect plug 81-2 of the control cable from the corresponding connector.
7. Disconnect the cores of the power cable from terminal stud 185 on terminal
board 835.
8. Place motor housing cover 812 down and secure it against rolling off.