7 Servicing/Maintenance
57 of 132
Amacan P
WARNING
Lubricant contaminating fluid handled
Hazard to persons and the environment!
▷
Using machine oil is only permitted if the oil is disposed of properly.
7.4.1.3 Lubricant quantity
Table 17:
Lubricant quantity [l] depending on size
Size
Lubricant quantity
[l]
700 - 470
1,8
800 - 540
2,2
900 - 540
2,2
1000 - 700
2,5
1200 - 870
3,8
1500 - 1060
7,0
1600 - 1060
5,0
7.4.1.4 Changing the lubricant
WARNING
Lubricants posing a health hazard and/or hot lubricants
Hazard to persons and the environment!
▷
When draining the lubricant take appropriate measures to protect persons and
the environment.
▷
Wear safety clothing and a protective mask if required.
▷
Collect and dispose of any lubricants.
▷
Observe all legal regulations on the disposal of fluids posing a health hazard.
WARNING
Excess pressure inside the pump set
Risk of injury when opening the pump set!
▷
Take care when opening the inner chambers. Equalise the pressure.
WARNING
Improper handling when placing the pump set in a vertical/horizontal position
Personal injury and damage to property!
▷
Select suitable lifting equipment for the size of the pump.
▷
Use appropriate means to secure the pump set against tilting, tipping over or
rolling off.
▷
Maintain a safe distance during lifting operations (load may swing when being
lifted).
▷
Use additional supports for the transport holder to secure it against tilting.