5 Installation at Site
28 of 132
Amacan P
WARNING
Pump set drops during the installation or removal process
Personal injury and damage to property!
▷
Never use the turnbuckle , shackle or discharge tube cover to lift the pump set.
▷
Always use lifting lug 59-47.
NOTE
Prior to fitting the turnbuckle, check that the corresponding split pin has not been
cracked and/or chipped. If damaged, always use a new split pin.
ü
Suitably sized lifting equipment is available.
ü
The support rope has been visually inspected.
ü
The split pin of the turnbuckle has been checked for any damage.
412.05
112
Fig. 11:
Inserting the O-ring
1. If not already fitted, insert the supplied O-ring 412.05 into pump bowl 112.
1
2 3
4
5
6
Fig. 12:
Lifting and positioning the pump set
2. Secure the lifting chain or lifting rope (1) to the trolley (4) of the lifting
equipment (2).
3. Attach the support rope (5) to the bail by its shackle. (
ð
Section 9.2, Page 94)
For a galvanised shackle, secure the pin at the shackle with Loctite 243.
For a stainless steel shackle, undo and tighten the pin twice and secure it with
Loctite 243.
4. Check that the support rope is arranged correctly.
ð
The free lifting lug (6) has to point away from the pump set
5. Partially unwind the support rope and electric cables.
6. Lower the pump set into the discharge tube until the bail is in an accessible
position, protruding from the discharge tube.
7. Securely cover the discharge tube except for a gap which allows work to
continue.