9 Related Documents
125 of 132
Amacan P
A
Bolted to the floor of the intake chamber
B
Flow-straightening vane centred beneath the discharge tube
C
Discharge tube
D
Intake chamber
Installation types BU, CU, DU
Table 60:
Dimensions [mm]
Size
h
R
s
1
s
2
s
R
(e
1
)
l
R
Design without
suction umbrella
d
8
Design with
suction umbrella
d
9
Design without
suction umbrella
d
8
Design with
suction umbrella
d
9
500 - 270
120
15
60
10
350
400
670
720
600 - 350
190
20
70
10
400
500
875
940
700 - 470
230
25
90
10
450
650
1000
1200
800 - 540
265
25
100
12
500
700
1165
1300
900 - 540
265
25
100
12
550
700
1165
1300
1000 - 700
335
30
120
12
600
900
1375
1675
1200 - 870
410
30
120
12
700
1100
1650
2050
1500 - 1060
515
40
140
12
850
1300
2050
2500
1600 - 1060
515
40
140
12
900
1300
2050
2500
Dimensions for installation types BG, CG, DG
h
R
l
R
45°
Fig. 64:
Flow-straightening vane for covered intake chamber
Table 61:
Dimensions [mm]
Size
h
R
s
1
s
2
s
R
l
R
500 - 270
120
15
60
10
430
600 - 350
190
20
70
10
545
700 - 470
230
25
90
10
650
800 - 540
265
25
100
12
740
900 - 540
265
25
100
12
790
1000 - 700
335
30
120
12
940
1200 - 870
410
30
120
12
1150
1500 - 1060
515
40
140
12
1450
1600 - 1060
515
40
140
12
1500
Adjust length I
R
of the flow-straightening vane to the 45° angle of the inlet
chamber.