The following greases can be used to lubricate the rolling element bearings:
Table 13: Lubricant characteristics
Base oil
Thickener
NLGI grade
(DIN 51518)
Worked
penetration
at 77 °F, 0.0039
inch
[25 °C, 0.1 mm
DIN 51818]
Pour point
(ISO 2176)
Application
temperature
range
Viscosity at
104 °F
[40 °C DIN
51562]
Ester oil
Polyurea
2
265 to 295
> 482 °F
[>250°C]
-40 °F to
+356 °F
[-40 °C to
+180 °C]
100
The maintenance intervals apply to the grease type with which the pump has been
pre-filled by the manufacturer:
Klüberquiet BQH 72-102, made by Klüber Lubrication München KG (
7.2.3.2.3 Grease quantity
Table 14: Grease quantity
Size
Grease quantity
Motor end
Pump end
700 - 470
200 cm
3
/ 0.05 gallons
600 cm
3
/ 0.16 gallons
800 - 540
200 cm
3
/ 0.05 gallons
600 cm
3
/ 0.16 gallons
900 - 540
200 cm
3
/ 0.05 gallons
600 cm
3
/ 0.16 gallons
1000 - 700
200 cm
3
/ 0.05 gallons
800 cm
3
/ 0.21 gallons
1200 - 870
200/230 cm
3
/ 0.05/0.06
gallons
800 cm
3
/ 0.21 gallons
1500 - 1060
230 cm
3
/ 0.06 gallons
1500 cm
3
/ 0.396 gallons
7.3 Drainage/disposal
WARNING
Fluids handled, consumables and operating supplies which are hot or pose a health
hazard
Hazard to persons and the environment!
▷
Collect and properly dispose of the flushing medium and of any residues of the
fluid handled.
▷
Wear safety clothing and a protective mask, if required.
▷
Observe all legal regulations on the disposal of fluids posing a health hazard.
1.
Always flush the pump if it has been used for handling noxious, explosive, hot
or other hazardous fluids.
2.
Always flush and clean the pump before transporting it to the workshop.
7.4 Dismantling the pump set
7.4.1
General information/Safety regulations
WARNING
Unqualified personnel performing work on the pump (set)
Risk of personal injury!
▷
Always have repair and servicing work performed by specially trained, qualified
personnel.
7 Servicing/Maintenance
38 of 68