6 Commissioning/Start-up/Shutdown
6.1 Commissioning/start-up
6.1.1
Prerequisites for commissioning/start-up
DANGER
Persons in the tank during pump operation
Electric shock!
▷
Never start up the pump set when there are persons in the tank.
WARNING
People falling into the unsecured discharge tube
Risk of personal injury!
▷
Take suitable precautions during the entire installation/dismantling process to
protect people from falling into the open discharge tube.
▷
Fence off the work area appropriately.
Before commissioning/starting up the pump set, make sure that the following
conditions are met:
▪
The lubricant has been checked.
▪
The direction of rotation has been checked.
▪
The pump set has been properly connected to the electric power supply and is
equipped with all protection devices.
▪
The pump set has been installed in the discharge tube as described in this
manual.
▪
The minimum fluid level has been reached.
▪
After prolonged shutdown of the pump (set), the activities required for returning
the pump (set) to service have been carried out.
Also see
●
6.1.2
Start-up
CAUTION
Re-starting while motor is still running down
Damage to the pump set!
▷
Do not re-start the pump set before it has come to a standstill.
▷
Never start the pump set while the pump is running in reverse.
✓
The fluid level is sufficiently high.
CAUTION
Start-up against a closed shut-off element
Damage to the pump set!
▷
Never start up the pump set against a closed shut-off element.
1.
Fully open the discharge line shut-off element, if any.
2.
Start up the pump set.
6 Commissioning/Start-up/Shutdown
Amacan P