WARNING
Hot surface
Risk of personal injury!
▷
Allow the pump set to cool down to ambient temperature.
DANGER
Improper transport
Danger to life from falling parts!
Damage to the pump set!
▷
Use the attachment point provided (eyebolt, lifting lug or bail) for attaching
lifting accessories.
▷
Never suspend the pump set by its power cable.
▷
Never use the chains or lifting ropes included in KSB's scope of supply for lifting
loads other than the KSB product supplied.
▷
Securely attach the lifting ropes or chains to the pump and crane.
WARNING
Improper lifting/moving of heavy assemblies or components
Personal injury and damage to property!
▷
Use suitable transport devices, hoisting equipment and lifting tackle to move
heavy assemblies or components.
WARNING
Excess pressure inside the pump set
Risk of personal injury when opening the pump set!
▷
Be careful when opening the inner chambers.
WARNING
Components with sharp edges
Risk of cutting or shearing injuries!
▷
Always use appropriate caution for installation and dismantling work.
▷
Wear work gloves.
WARNING
Pump set tipping over or rolling off
Risk of personal injury!
▷
Make sure the pump set is secured against tipping over during the entire
dismantling process.
▷
For dismantling the pump set in horizontal position, secure it against rolling
off.
Observe the general safety instructions and information.
For dismantling and reassembly observe the general assembly drawing.
In the event of damage you can always contact our service staff.
7.4.2
Preparing the pump set
1.
Interrupt the power supply and secure the pump against unintentional start-up.
2.
Remove the pump set from the discharge tube.
3.
Clean the pump set.
4.
Drain the lubricant.
7 Servicing/Maintenance
Amacan P