Filling in the lubricant
Fig. 14: Filling in the lubricant
FD
Always apply a liquid sealing agent (e.g. Hylomar SQ32M) to sealing
surfaces marked with this symbol.
1.
Place the pump set in horizontal position and make sure it cannot roll off.
2.
Remove screw plug 903.03.
3.
Remove screw plug 903.01 and joint ring 411.01.
4.
Screw in a sufficiently long tube with G
1
/
2
" thread.
5.
Fill the lubricant in through the tube.
6.
Remove the tube. Fit screw plug 903.01 and joint ring 411.01 with liquid
sealant.
7.
Re-insert and tighten screw plug 903.03.
7.2.3.2
Lubricating the rolling element bearings
7.2.3.2.1 Intervals
Change the grease when carrying out a general overhaul but at least every 5 years.
7.2.3.2.2 Grease quality
CAUTION
Mix of different grease types
Damage to the pump set!
▷
Make sure to use the right type of grease.
▷
Never mix different types of grease.
7 Servicing/Maintenance
Amacan P
37 of 68